Formulation platforms

Specialty formulation development, platform by platform

Some products need more than a plain tablet, and that is where specialty formulation development comes in. Below are the platforms we work on, what makes each one hard, and how we handle it. For every platform, we develop the formulation and its analytical methods, run the stability studies, and transfer the process to your plant.

Platform 01

Delayed release formulation development

A delayed release product must survive the stomach and release in the intestine. That matters for acid-labile drugs such as the proton pump inhibitors, and for drugs that irritate the stomach. The hard part is usually not the enteric polymer. Instead, it is the seal coat that keeps an acidic polymer away from an acid-sensitive drug. It is also a coating process that gives the same film on every tablet. We test acid resistance with the two-stage method: two hours in 0.1 N HCl, then buffer at pH 6.8.

What we do

  • Enteric-coated tablets, capsules and pellets
  • Seal coat design for acid-labile drugs
  • Two-stage dissolution methods
  • Coating process scale-up

Platform 02

Orally disintegrating tablet (ODT) formulation

FDA guidance expects an ODT to disintegrate within about 30 seconds. However, a tablet soft enough to do that is often too fragile to survive a blister and a shipping carton. So ODT development is a balance between disintegration time, hardness and friability. Taste matters as well, because the drug dissolves in the mouth. We work with superdisintegrants, sugar-alcohol bases and taste-masking coats, and we choose packs that keep moisture out.

What we do

  • Directly compressed ODTs
  • Taste masking of bitter drugs
  • Disintegration and friability balance
  • Moisture-protective pack selection

Platform 03

MUPS formulation development

A multiple unit pellet system puts hundreds of coated pellets into one tablet. Each pellet behaves like a small dose, so gastric emptying varies less than with a single large unit. The risk sits at compression: press too hard and the functional coat cracks, and the product loses its release control. Therefore, we design flexible coats and cushioning excipients, and we test release after compression, not only before it.

What we do

  • Drug layering and extrusion-spheronization
  • Functional coats that survive compression
  • Cushioning excipient selection
  • Release testing before and after compression

Platform 04

Nutraceutical formulation development

Nutraceuticals often carry ten or more actives in one tablet. Some of them, such as vitamin C and several B vitamins, degrade quickly. As a result, the label claim has to hold at the end of shelf life, not only on the day of manufacture. We bring pharmaceutical methods to this work: compatibility studies, justified overages, validated assays for each active, and real stability data behind every claim.

What we do

  • Multivitamin and mineral tablets
  • Herbal extract and probiotic products
  • Overage design backed by stability data
  • Assay methods for multi-active products

Platform 05

Solubility and bioavailability enhancement

Many new drugs are poorly soluble, and a drug that does not dissolve is not absorbed. The fix depends on why it does not dissolve. Some drugs only need smaller particles. Others need an amorphous solid dispersion, a cyclodextrin complex, a lipid-based system or a different salt. We start from preformulation data to pick the route. Then we check that the chosen form stays stable, because an amorphous drug that recrystallizes on the shelf loses its advantage.

What we do

  • Route selection from BCS class and preformulation data
  • Solid dispersions, complexes and lipid systems
  • Biorelevant dissolution testing
  • Physical stability checks by XRPD

Platform 06

Injectable formulation development

Injectables leave less room for error than oral products. The pH, tonicity and particulate matter all have tight limits, and the formulation has to stay compatible with its vial, stopper or syringe. For products that are not stable in solution, freeze-drying adds a cycle that must work at commercial scale. We develop solutions, suspensions and lyophilized products, and we plan the sterilization approach early, because it shapes the whole formulation.

What we do

  • Solutions, suspensions and lyophilized products
  • pH, buffer and tonicity design
  • Container closure compatibility
  • Particulate matter and stability testing

Platform 07

Biosimilar formulation development

A biologic can unfold, aggregate or lose activity, even when stored correctly. For a biosimilar, the formulation must protect the protein and keep it comparable to the reference product throughout shelf life. So we screen buffers, sugars and surfactants for their effect on aggregation and charge variants. Then we run stability studies to ICH Q5C with methods that can see these changes.

What we do

  • Buffer and excipient screening
  • Aggregation and degradation studies
  • Comparability with the reference product
  • Stability studies to ICH Q5C

Frequently Asked Questions

What is a formulation platform? +

It is the technology a product is built on. Examples include an enteric-coated tablet, an orally disintegrating tablet, a pellet system and a lyophilized injectable. Each platform has its own excipients, process steps, test methods and scale-up risks.

Can you move an existing product to a new platform? +

Yes. This is one of our most common projects, for example an immediate release tablet becoming an ODT or a delayed release product. We keep what works in the current formulation, then develop and test the new platform around it.

Which platform suits a poorly soluble drug? +

It depends on why the drug does not dissolve and on the dose. Particle size reduction may be enough for some drugs. Others need a solid dispersion, a complex or a lipid system. Preformulation data tell us which route to test first.

Do you also work on nutraceuticals? +

Yes. We apply pharmaceutical development and testing methods to supplement tablets, capsules and powders, including assays and stability data for each label claim.

What makes a tablet an ODT? +

An orally disintegrating tablet breaks up in the mouth without water. FDA guidance is commonly cited as expecting disintegration in about 30 seconds and a tablet weight of no more than 500 mg. The tablet also has to survive packing and shipping, which is the harder part.

Why choose MUPS over a single enteric-coated tablet? +

The dose is spread over many coated pellets, so a fault in one pellet releases only a small part of it. Pellets also leave the stomach more evenly than a single large unit, which can reduce variation between patients. The trade-off is a harder compression step.

Show all 14 questions
How do you stop pellet coats cracking during compression? +

We use a flexible coat, cushioning excipients between the pellets and a controlled compression force. Pellet size and the share of pellets in the tablet matter too. We compare release before and after compression to show that the coat held.

Is an ODT automatically bioequivalent to the conventional tablet? +

No. Faster disintegration, or some absorption in the mouth, can change the profile for some drugs, so equivalence has to be shown for each product. Tell us the drug and market and we will look at what the authority is likely to expect.

What is the difference between delayed and extended release? +

Delayed release holds the drug back until a later point, usually until it has left the stomach. Extended release lets the drug out gradually over a longer time. Both are types of modified release, and one product can combine them.

Why does an enteric-coated tablet fail the acid stage? +

Usual causes are a coat that is too thin or uneven, cracks or chips at the edges, poor film formation or a core that swells. Coating conditions and curing often play a part. We look at the film and the core together before changing the formula.

How do spray drying and hot melt extrusion differ? +

Both can make amorphous solid dispersions. Spray drying uses a solvent and exposes the drug to less heat. Hot melt extrusion avoids organic solvents, but the drug must tolerate the melt temperature. The choice depends on the heat stability and solubility of the drug and on the polymer.

When should an injectable be freeze-dried? +

Usually when the drug is not stable enough as a solution for a practical shelf life, and a change of pH, buffer or storage temperature does not solve it. A liquid is simpler to make and use, so we test that option first.

What is collapse temperature in lyophilization? +

It is the product temperature above which the frozen material loses its structure during primary drying. Drying above it can give a collapsed cake. It is measured early, often by freeze-dry microscopy, because it guides the formulation and the cycle.

Must a biosimilar have the same formulation as the reference product? +

Not always. Some differences in inactive ingredients can be acceptable if data show no clinically meaningful effect on safety or effectiveness. Route, strength and dosage form are held closer to the reference. We check the rules of the target market before screening.