Stability Testing & Analysis

Stability Testing Services for Drug Products

Every shelf life is a forecast. The data decide how far it reaches.

Our stability testing services take a product from the first development batch to the data in the dossier. We write the protocol for your markets, test each time point, watch the trend and propose a shelf life you can defend.

Clients served
800+
Countries
64
Stability chamber shelves holding packed samples at controlled temperature and humidity

Decisions to make before samples go in

Which markets?

The climatic zone sets the long-term condition. A study at 25 °C/60% RH will not support a market that expects 30 °C/75% RH. If you may sell there later, the cheaper moment to decide is now.

Which pack?

A bottle and a blister can give one tablet two different lives. Running both on an early batch often settles the question while changing pack is still easy.

Which methods?

A method changed halfway leaves two sets of data that may not compare. So the methods should see the degradants, and be settled, before the first sample is pulled.

What our stability testing services include

Protocol. Batches, packs, orientation, conditions, time points, tests and limits. Reduced designs such as bracketing or matrixing are considered where strengths or packs are close enough to justify them.

Testing. Assay, degradants, dissolution and water for most oral solids. Sterile products bring particulate matter, pH and sterility-related tests. We also cover release testing of development batches, so day zero is measured the same way as the rest.

Photostability. The ICH minimum is 1.2 million lux hours of visible light and 200 Wh/m² of near UV. We test the exposed product first, then the pack if the product changes. The result decides the pack and the label statement.

Trend review. Results are plotted as they arrive. A value inside its limit can still be wrong for its trend, and that is worth knowing two time points before it fails.

Shelf life. The summary compares long-term and accelerated data and proposes a shelf life with the statistics behind it. It's written to fit section 3.2.P.8.

What we assess

  • Long-term
  • Accelerated
  • Intermediate
  • Photostability
  • In-use

What you receive

  • Stability protocol ready for your QA approval before samples are stored.
  • Time point results test reports with the data needed for your file.
  • Photostability report exposure record, results and the label conclusion.
  • Trend review plots and a note on anything drifting.
  • Stability summary tables, evaluation and the proposed shelf life and storage statement.

ICH Q1 is changing

ICH has reported the adoption of a consolidated Q1 guideline in November 2026. It brings Q1A to Q1F and Q5C into one text. Each region then sets its own implementation date, so the existing guidelines stay relevant in the meantime.

For a study starting now, we check the protocol against both, so it does not need explaining later.

  • ICH Q1A(R2) conditions, batches and study design.
  • ICH Q1B photostability exposure and testing.
  • ICH Q1D and Q1E reduced designs and data evaluation.
  • ICH Q5C stability of biological products.
  • WHO TRS 1010, Annex 10 conditions for hot and humid markets.

Who it's for

  • Developers putting exhibit batches on stability
  • Companies filing in several climatic zones
  • Products changing pack, site or supplier
  • Nutraceutical brands supporting label claims

When a study is needed

Before filing, on exhibit batches. During development, on prototypes, where a short study can end a bad formula early. After approval, when the pack, supplier or manufacturing site changes.

Nutraceuticals need it as well. A vitamin claim has to hold on the last day of shelf life, and vitamins are among the least patient ingredients there are.

Why keep stability close to development

When a degradant appears, the first question is where it comes from. The people who ran the compatibility and stress studies can usually answer faster than a lab that sees only the sample.

The data then feed the Module 3 sections that describe the product.

Part of the Indivirtus group

Group companies
6
Clients across the group
800+
Countries
64

Frequently Asked Questions

What are the ICH stability conditions? +

Long-term storage depends on the climatic zone: 25 °C/60% RH for zones I and II, 30 °C/65% RH for IVa and 30 °C/75% RH for IVb. Accelerated storage is 40 °C/75% RH. An intermediate condition of 30 °C/65% RH comes in when accelerated samples change significantly. Refrigerated and frozen products have their own sets.

How many batches go on stability? +

ICH Q1A(R2) asks for three primary batches, at least two of them pilot scale. Generic filings have market-specific rules on number and size, so check the target agency first. Development studies can use a single batch, because their purpose is to choose, not to file.

Can accelerated data alone support a shelf life? +

They support a forecast, but long-term data anchor it. How far you can extrapolate depends on the length of the long-term data, whether accelerated samples changed and how much the results vary. ICH Q1E sets out the steps. A claim at its outer limit should be a decision, not a default.

Is photostability testing always required? +

It is expected for new drug substances and products. For generics and later changes it depends on the market and on what is known about the molecule. It is worth doing whenever the pack is clear or the drug is known to be sensitive, since the result also decides the label and pack.

What is the difference between OOS and OOT? +

An out-of-specification (OOS) result breaks a limit. An out-of-trend (OOT) result may be within limits but does not fit its own history. The first triggers a formal investigation. The second deserves a look before it becomes the first, and the protocol should say how that look is done.

What is bracketing and matrixing? +

Two ways to test less without losing the conclusion. Bracketing tests only the extremes, for example the lowest and highest strength. Matrixing tests a planned part of the samples at each time point. Both need similar products and a written justification, and a reviewer may ask you to defend it.

Show all 7 questions
What does the new ICH Q1 guideline change? +

It puts the Q1 series and Q5C into a single document. For a given study, what changes depends on the final text and on when your region implements it. We compare your protocol with both versions and tell you where they differ, rather than assuming either one.